Where I need to replace my Copeland Compressor Part CR42K6-TF5-230.By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them.
By chatting and providing personal info, you understand and agree to our Terms of Service and Privacy Policy. HVAC Have HVAC questions Ask an HVAC Expert for answers Connect one-on-one with 0 who will answer your question By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them. Ask an Expert Home Improvement Questions HVAC Questions This answer was rated: What are acceptable impedance readings on a Copeland scroll What are acceptable impedance readings. What are acceptable impedance readings on a Copeland scroll compressor between the three winding pins 3 ton. Reading Copeland Compressor Model Numbers Trial Buildings VerifiedModel. ZR32R5 PFV Show More Show Less Ask Your Own HVAC Question Share this conversation Customer reply replied 3 years ago The is no continuity to ground Answered in 28 minutes by: 712017 HVAC Technician: Daniel Plourde, HVAC Technician replied 3 years ago Daniel Plourde, HVAC Technician Category: HVAC Satisfied Customers: 696 Experience: Ive been in the HVAC buisness since 2008 working on residential, commercial, and industrial buildings Verified hi i am dan i can help you with this. The lowest resistance will be found between run(R) to common(C). The resistance between start(S) to common(C) is typically three-to-five times higher than run to common winding, and finally, the resistance between run and start should be the sum of S to C and R to C Ask Your Own HVAC Question Customer reply replied 3 years ago Those reading match. The breaker blew. We tapped the compressor with a rubber mallet in case it was froze but that jiggle now shows 2 of 3 compressor pins have continuity to ground. Bad compressor Customer reply replied 3 years ago 1st part of tag image0.jpg image0.jpg Customer reply replied 3 years ago 2nd half image0.jpg image0.jpg HVAC Technician: Daniel Plourde, HVAC Technician replied 3 years ago if any of the pins have continuity to ground then the compressor is bad it may have been weak and by tapping it made it connect better. ![]() That is what it did Thank you HVAC Technician: Daniel Plourde, HVAC Technician replied 3 years ago keep in mind that because the compressor is grounded the oil is now burnt and if you decide to replace the compressor it will require flushing the lines and adding burn driers to the system. Reading Copeland Compressor Model Numbers Serial 09I086 ReadDaniel Plourde, HVAC Technician Category: HVAC Satisfied Customers: 696 Experience: Ive been in the HVAC buisness since 2008 working on residential, commercial, and industrial buildings Verified Daniel Plourde and 87 other HVAC Specialists are ready to help you Ask your own question now Was this answer helpful Yes No Finish How JustAnswer works Describe your issue The assistant will guide you Chat 1:1 with a hvac technician Licensed Experts are available 247 100 satisfaction guarantee Get all the answers you need Ask Daniel Plourde Your Own Question Daniel Plourde, HVAC Technician Category: HVAC Satisfied Customers: 696 696 Satisfied Customers Experience: Ive been in the HVAC buisness since 2008 working on residential, commercial, and industrial buildings Daniel Plourde is online now Get an Answer Continue Share this conversation See more Related HVAC Questions I am looking for an emerson copland compressor or a cross i am looking for an emerson copland compressor or a cross reference for a ZR61K3PFV Model sx5hp serial 09I086 read more airheatman Heating Air Conditioning Contractor 6 years college 11,583 satisfied customers Needing a replacement compressor for a carrier 38YRA024310, Needing a replacement compressor for a carrier 38YRA024310 read more airheatman Heating Air Conditioning Contractor 6 years college 11,583 satisfied customers I have just installed a new copeland compressor ( model I have just installed a new copeland compressor ( model zr48k53-pfv-7me)and it won start. Any place else on or in the unit that they would have placed any info so I can tra read more airheatman Heating Air Conditioning Contractor 6 years college 11,583 satisfied customers My lennox compressor is out. Just a week. I am trying to Can I get a compressor from ebay and use a hvac technician to fix it. Can I replaced the compressor with a copeland cr42k6-pfv rated at 42000 btu read more airheatman Heating Air Conditioning Contractor 6 years college 11,583 satisfied customers MY AIR CONDITIONER IS MAKING AN INTERMITING HUMMING NOISE. AFTER REMOVING THE SERVICE PANEL I FOUND OUT IT WAS THE ELECTRIC JUNCTION BOX ON THE SCROLL PUMP.TO THE BEST OF read more Phil Consultant to Engrs, Govt Contractors Degree, Mech Engr Technology 11,455 satisfied customers Only rarely do I need 8 ton. How do you suggest modulating the system Can I run a ZR94KCE with a Variable frequency drive at 50 R22 suction runs about 60psi and head pre read more Phil Consultant to Engrs, Govt Contractors Degree, Mech Engr Technology 11,455 satisfied customers Need a copeland compressor that will replace a Bristol need a copeland compressor that will replace a Bristol H23B28SABCA heat pump compressor (circa yr2000) read more Daniel Plourde HVAC Technician Vocational, Technical or Trade School 696 satisfied customers I just purchase a doublw wide home. The compressor internally I just purchase a doublw wide home. The compressor internally cycles on off as soon as unit is turned on. I replace cap. Its resistance is 1 ohm, and 2ohm read more airheatman Heating Air Conditioning Contractor 6 years college 11,583 satisfied customers Please tell me which type of compressor I need for Lenox 13ACD-048. Please tell me which type of compressor I need for Lenox 13ACD-048. Thank you kindly. Msgr. A. M. Nikolic read more Brian HVAC Guy HVAC Technician High School 1,029 satisfied customers How can I remove excess oil from copeland scroll compressor, How can I remove excess oil from copeland scroll compressor, model ZRA8K3-PFV The compressor is installed in the system. Referigant charge was lost then condenser coil was punctured. I recharged the read more gotoman for ac HVAC Service manager and owner Associate Degree 5,468 satisfied customers I need to replace my Copeland Compressor Part CR42K6-TF5-230.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |